Commercial ind res air mrine
arcflash about contact testimonials

Infrared Inspections - Commercial

comm main

Satisfy insurance requirements, reduce insurance premiums and save significant amounts of time and money!

ELECTRICAL SYSTEMS
ROOFING SYSTEMS
BUILDING ENVELOPE & STRUCTURES

Main service entrance inspections
Switch gear, sub-panels, breakers, distribution panels, disconnects, etc.
Power generation inspections
HVAC heating and cooling coils, heating equipment
Motors & mechanical equipment

Commercial & Industrial Flyer (PDF)PDF
Global Asset Protection GuidelinesLOADING

 

 

 

Roof leak detection for buildings, plants, facilities
Identify water damaged portions of a roof quickly and accurately
Locate water intrusion locations
Eliminate unnecessary demolition and replacement of good roofing materials
Plan accurate budgets based on facts
Document problems before the warranty/bond expires

 

 

 

Thermal heat loss inspections for homes, buildings, plants, facilities, etc.
Locate radiant in floor heating wires or pipes
In-floor heating system inspections for leaks and/or temperature distribution
Water damage inspections in buildings, condo’s plants and facilities
Pinpoint moisture intrusion locations
Locate missing or damaged insulation
Identify air leakage and energy losses
Evaluate the thermal performance of retrofits and remodels
Building integrity inspections

 

Electrical System Inspections: Abnormal heating is associated with possible and potential failures.

Contact Problems: Heating is produced by the current flow through a contact with higher than normal electrical resistance, or load demand. This type of problem is typically associated with switch contacts and connectors.

The actual point of heating may often begin very small and continue to expand until it becomes a serious problem. An Infrared Inspection will easily identify such thermal problems and provide the information to correct the problems before they become a failure or fire hazard.

Electrical Distribution: Literally hundreds of different components make up an electrical system. These components are comprised of main distribution panels, transformers, switchgear, breakers, meters, local power distribution panels, appliance panels, motors and PDUs. Utilizing Thermography as part of your Predictive Maintenance Program (PdM) will help to reduce impending electrical problems eliminating costly down time, enabling you to schedule repairs and maintenance.

CTI uses InspecTrend™ Best Practice Infrared PdM Inspection Software (InspecTrend .pdf) Which is the finest IR reporting software in the industry.

LOADING!

Don't Let This Happen To Your Equipment!

To the left is an example of a 1,200 AMP breaker and an MDP that was taken out during an Arc Flash explosion, causing significant expense and down time. Don't let this happen to you. Call and schedule an Infrared Electrical Inspection Today and avoid this kind of costly, and possibly dangerous damage.

More Arc Flash Analysis Information

LOADING
InspecTrend

Certified

Solution Provider

Infrared PdM

Inspection

Management System

Water leakage is the number one factor leading to the damage of framing structures, finishes and roofing systems.

Though most of these problems remain hidden from normal viewing, Infrared Inspecions can detect and measure the efficiency of a building in a non-invasive way. This allows you to detect potential problems before they can create structural damage, eliminating lost revenue due to inefficient systems.

Most leaks occur where the waterproofing is sealed or where there is a penetration of the roof. Since most types of roof systems absorb some amount of water, it is harder to find the exact spot of water contamination in the underlying insulation because it may not leak into the building until it has absorbed all the water it can hold. Many of the problems that might exist within a roofing system remain hidden from normal viewing.

10 Reasons Why Built Up Roof Systems Leak (PDF)PDF

     

Locate the intrusion points on the roof noninvasively, quickly and inexpensively; Save time and money.

Roof Maintenance. Water leakage is the number one factor leading to damages of roofing structures, framing structures and interior finishes. Waterproofing problems for roofs occur in two ways: leakage and moisture contamination. Leakage is often times obvious, although the leak inside the building rarely directly relates to the exact entry spot on the roof, since the water flows down the slope of the roof to a spot that is not sealed and into the building at that point and possibly others.

Thermal imaging cameras can detect and measure the efficiency of a roof’s integrity in a non-invasive way and therefore you don’t have to remove and destroy good remaining roofing material in order to locate the source of a roofing system problem. You can also detect potential problems to a roofing system that may occur in the near future and thereby avoid potentially expensive future repairs.

 


• ITC Certified Thermographers • Experienced & Licensed Electricians
PO Box# 2131 Redmond , WA 98073-2131 (425) 861-3887

email address

Top

Home - Industrial - Residential - Aerial - Marine - Arc Flash - About - Read Legal Doccument.

Cascade Thermal Imaging Inc, Infrared Inspection, Redmond, WA